THIS TONER CARTRIDGE DOES NOT HAVE INTEGRATED DRUM UNIT.  THE DRUM IS A SEPARATE UNIT FROM THE TONER CARTRIDGE. This is a compatible cartridge so there will be some differences between this cartridge and the OEM.  These differences will not affect the function.

 

Not Recognizing  Verify you have the correct cartridge for your specific printer model.   This cartridge uses a RF or radio frequency sensor chip that’s located on the bottom of the cartridge. This chip does not make physical contact with the printer but rather sits in a specific position to be picked up by the printer’s sensor. Make sure that the cartridge is properly inserted and locks into place to ensure the chip is in the correct position. If the problem persists it is most likely an issue with the chip on the cartridge.

 

To remove and install this toner cartridge into the Kyocera Mita FS1030MFP/1035MFP/1135MFP printers do the following; –          Open the front cover.

 

–          Turn the toner container lock lever to the unlock position.  Push the toner container lock lever to the position marked by the arrow and pull out the toner container.

 

–          Install the new toner container into the printer.  Push firmly on the top of the toner container until you hear a click.

 

–          Turn the toner container lock lever to the lock position.

 

–          Close the front cover   Kyocera Mita requires to clean the printer any time the toner cartridge has been replaced.  Failure to do so may result in print quality issues.  To clean the printer do the following; –          Open the front cover.

 

–          Lift the developer together with the toner container out of the printer.

 

–          Remove the drum unit from the printer by holding the green levers with both hands.

 

–          Use a clean, lint-free cloth to clean dust and dirt away from the metal registration roller.

 

–          On the drum unit, slide the main charger cleaner (green) back and forth 2 or 3 times to clean the charger wire, then return it to its original position.

 

–          When cleaning is complete, return the drum unit to the original position.

 

–          Return the developer unit to its position, aligning the guides at both ends with the slots in the printer.  Then, close the front cover.

 

–          Close the front cover.   Print Quality Issues  Make sure the above cleaning steps were completed when the new toner cartridge was installed.   There’s a piece of tape on the toner cartridge which must be removed prior to installation.

 

Gently shake and roll the toner cartridge a few times to loosen and redistribute the toner powder inside the cartridge.

 

Streaking, lines, ghost images, and repeating image defects are drum related issues.  The drum unit is separate from the toner cartridge.   Not Fitting   Verify you have the correct cartridge for your specific printer model.  Check to make sure the cartridge is being installed in the correct orientation.  Check the inside of the printer for any obstructions that may be causing the cartridge not to fit properly.  Check the cartridge itself for physical damage.